SERVICE & SUPPORT

FAQ

We provide DC Isolation Switch, Miniature Circuit Breaker, DC Surge Protector, Rapid Shutdown, Micro Inverter, Smart Electricity Meter and other components for Solar and Energy Storage System use.

A:
Both input and output are AC.
A:
Overtemperature protection, Emergency stop button shutdown, AC side power loss shutdown.
A:
Fristly select the number of RSD strings according to the number of PV strings, and then select the detailed parameter specifications according to the string voltage and current.
A:
1-2 strings, 3-5 strings, 6-10 strings, each type has a different shell
A:
We have 1-in-1, 2-in-1, 4-in-1, 6-in-1, 4 types of models, output power range cover from 300W to 3000W.
A:
T1 is mainly for outdoor distribution box,T2 is mainly for indoor distribution box, T1+T2 means that it is suitable for indoor + outdoor.
A:
For example, PEJB-3-1 represents 3 strings of input and 1 string of output, and multiple string are combined into one, the output current is increased, and the voltage is unchanged.
A:
Measurement function and Data transmission function. Support RS485, Bluetooth, WIfi Communication.
A:
Shunt release is a remotely operated switching attachment. When the power supply voltage is equal to any voltage between 70% and 110% of the rated control power supply voltage, the circuit breaker can be reliably broken.
A:
TUV,CB,UL,CE,SAA,TUV+AU,UKCA
A:
1.System Voltage The rated operating voltage of DC isolator should be equal to or greater than the system requirements. Common ones meet UL508i, IEC60947-3 600V, 1000V and 1500V. System voltages usually connected to single-phase inverters are up to 600V, and three-phase series inverters or centralized inverters are up to 1000V or 1500V.
2. Number of strings
2-pole - single string, 4-pole - double string, etc.
For inverter built-in DC isolators, the number of MPPT of the inverter determines the pole of the DC isolator.

SEARCH

%{tishi_zhanwei}%